1. When the floor heating water manifold is used for the first time, it needs to inject hot water to start the geothermal heat. The specific steps are to open the main water supply loop valve of the water manifold, and then gradually increase the temperature of the hot water to the pipeline and then circulate. Check the excuses of the water manifold for water leakage, and then gradually open the valves of each branch of the water manifold. If there is water leakage in the pipeline, please close the water supply valve in time, and notify the geothermal or the developer to come to deal with the problem.
2. The floor heating water manifold controls the heating temperature of each room or their own area respectively. Users can adjust the temperature of each room according to their own needs. After the manual exhaust valve of the water manifold is used, remember to remove the air in the floor heating water manifold. Exhaust it cleanly, so as to ensure the heating temperature of each pipeline and the fluidity of water flow.
3. There is a filter in the front section of the water manifold. When the user uses it for three or five months during the heating period every year, the filter should be cleaned once to ensure the cleanliness of the water pipe. After the heating is over, the filter should be cleaned with clean water. Rinse well.
4. There is a process for heating. Generally speaking, the temperature cannot be felt immediately after turning on the floor heating. Under normal circumstances, the temperature can reach the preset effect after two to six days, but pay attention, the water temperature of the floor heating should not exceed 65 degrees Celsius.
5. If you are not at home for a long time, or you do not use the floor heating water manifold for a long time, it is recommended to reduce the total valve of the floor heating water separator before going out, but do not close it completely. If it is determined that it will not be used for a long time, then turn off the floor heating Be sure to blow dry the water pipe before closing it.